| Assessment Year | 2016 |
|---|---|
| Principal Product | Upholstered furniture |
| NAICS | 337121: Upholstered Household Furniture Manufacturing |
| SIC | 2512: Wood Household Furniture, Upholstered |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
84,000
ft2
|
| Annual Production | 38,000
units
|
| Production Hrs. Annual | 2,500
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $68,687 | 741,792 |
kWh
|
$0.093 |
| Electricity Demand | $16,699 | 3,765 |
kW-mo/yr
|
$4.44 |
| Electricity Fees | $860 | - |
|
- |
| Natural Gas | $15,407 | 2,007 |
MMBtu
|
$7.68 |
| TOTAL YEARLY COSTS | $101,653 | |||
| RECOMMENDED SAVINGS* | $22,253 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,377 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,102 | $41,992 |
$11,506
128,561
kWh
|
$2,900
-
kW-mo/yr
|
- | $2,696 | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $497 | $606 |
$388
4,340
kWh
|
$96
-
kW-mo/yr
|
- | $13 | |
| 03 | 2.7135: Install occupancy sensors | $362 | $400 |
$362
4,040
kWh
|
- | - | - | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $1,219 | $180 |
$1,219
9,488
kWh
|
- | - | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $416 | $200 |
$611
4,756
kWh
|
$155
-
kW-mo/yr
|
$(-150.0) | $(-200.0) | |
| 06 | 2.6218: Turn off equipment when not in use | $480 | $1,600 |
$480
5,358
kWh
|
- | - | - | |
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $266 | $100 |
$227
1,764
kWh
|
$39
-
kW-mo/yr
|
- | - | |
| 08 | 2.4151: Develop a repair/replace policy | $1,911 | $5,685 |
$1,464
16,357
kWh
|
$447
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $22,253 | $50,763 |
$16,257
174,664
kWh
|
$3,637
-
kW-mo/yr
|
$(-150.0) | $2,509 | ||
| TOTAL IMPLEMENTED | $18,377 | $43,198 |
$12,867
141,697
kWh
|
$3,151
-
kW-mo/yr
|
$(-150.0) | $2,509 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||