Assessment Year | 1988 |
---|---|
Principal Product | ELECTRICAL TRANSFORMERS |
NAICS |
n/a
|
SIC | 3612: Power, Distribution, and Specialty Transformers |
Sales Range | $50 M to 100M |
# of Employees | 450 |
Plant Area |
n/a
|
Annual Production | 1,324,000
pieces
|
Production Hrs. Annual | 6,204
hrs
|
Location (State) | Mississippi |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $437,199 | 7,313,892 |
kWh
|
$0.060 |
Natural Gas | $255,664 | 60,291 |
MMBtu
|
$4.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,836 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $213 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,400 | $600 | - |
$2,400
-
MMBtu
|
|
02 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $226 | $79 | - |
$226
-
MMBtu
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,117 | - |
$5,117
123,095
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $1,880 | $3,533 |
$1,880
44,549
kWh
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $213 | $208 |
$213
4,689
kWh
|
- | |
TOTAL RECOMMENDED | $9,836 | $4,420 |
$7,210
172,333
kWh
|
$2,626
-
MMBtu
|
||
TOTAL IMPLEMENTED | $213 | $208 |
$213
4,689
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs