Assessment Year | 2013 |
---|---|
Principal Product | Case good furniture |
NAICS | 337122: Nonupholstered Wood Household Furniture Manufacturing |
SIC | 2511: Wood Household Furniture, Except Upholstered |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
184,687
ft2
|
Annual Production | 23,000
pieces
|
Production Hrs. Annual | 2,117
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $115,631 | 1,756,000 |
kWh
|
$0.066 |
Electricity Demand | $30,552 | 7,804 |
kW-mo/yr
|
$3.91 |
Fuel Oil #6 | $19,500 | 975 |
MMBtu
|
$20.00 |
Wood | $1 | 8,700 |
MMBtu
|
$0.000 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,455 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,160 | $7,564 |
$857
13,013
kWh
|
$303
-
kW-mo/yr
|
- | - | |
02 | 2.7135: Install occupancy sensors | $1,833 | $1,524 |
$1,833
27,833
kWh
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $195 | $61 |
$144
2,189
kWh
|
$51
-
kW-mo/yr
|
- | - | |
04 | 2.7124: Make a practice of turning off lights when not needed | $1,051 | $825 |
$1,051
15,937
kWh
|
- | - | - | |
05 | 2.4151: Develop a repair/replace policy | $950 | $4,258 |
$702
10,663
kWh
|
$248
-
kW-mo/yr
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $856 | $820 |
$582
8,836
kWh
|
$274
-
kW-mo/yr
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $410 | $100 |
$702
10,660
kWh
|
$248
-
kW-mo/yr
|
$(-300.0) | $(-240.0) | |
TOTAL RECOMMENDED | $6,455 | $15,152 |
$5,871
89,131
kWh
|
$1,124
-
kW-mo/yr
|
$(-300.0) | $(-240.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs