Assessment Year 2013
Principal Product Tapered bearings
NAICS 332991: Ball and Roller Bearing Manufacturing
SIC 3562: Ball and Roller Bearings
Sales Range $50
M
to 100
M
# of Employees 285
Plant Area 211,000
ft2
Annual Production 200,000
pieces
Production Hrs. Annual 7,800
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,135,840 54,384,000
kWh
Electricity Demand $751,887 83,424
kW-mo/yr
Electricity Fees $11,811 -
Natural Gas $225,168 34,915
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $351,585 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $83,575

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.1311: Replace electrically-operated equipment with fossil fuel equipment $240,743 $750,000 $406,244
10,344,888
kWh
$119,688
-
kW-mo/yr
$(-285,189.0)
-
MMBtu
-
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $18,552 $69,000 $11,568
294,587
kWh
$6,984
-
kW-mo/yr
- -
03 2.7447: Install vinyl strip / high speed / air curtain doors $8,715 $20,000 $5,071
127,671
kWh
$3,644
-
kW-mo/yr
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $80,247 $134,713 $64,302
1,637,440
kWh
$17,913
-
kW-mo/yr
- $(-1,968.0)
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,537 $18,520 $1,984
50,525
kWh
$553
-
kW-mo/yr
- -
06 2.7124: Make a practice of turning off lights when not needed $791 $50 $619
15,755
kWh
$172
-
kW-mo/yr
- -
TOTAL RECOMMENDED $351,585 $992,283 $489,788
12,470,866
kWh
$148,954
-
kW-mo/yr
$(-285,189.0)
-
MMBtu
$(-1,968.0)
TOTAL IMPLEMENTED $83,575 $153,283 $66,905
1,703,720
kWh
$18,638
-
kW-mo/yr
- $(-1,968.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs