Assessment Year | 2013 |
---|---|
Principal Product | Railroad ties and utility poles |
NAICS | 321114: Wood Preservation |
SIC | 2491: Wood Preserving |
Sales Range | $5 M to 10M |
# of Employees | 90 |
Plant Area |
159,675
ft2
|
Annual Production | 1,080,000
pieces
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | South Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $89,289 | 1,727,040 |
kWh
|
$0.052 |
Electricity Demand | $21,985 | 2,590 |
kW-mo/yr
|
$8.49 |
Electricity Fees | $(-2,541.0) | - |
|
- |
Natural Gas | $117,454 | 25,280 |
MMBtu
|
$4.65 |
Wood | $1 | 72,000 |
MMBtu
|
$0.000 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,959 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,752 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $481 | $1,490 |
$375
7,258
kWh
|
$106
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,008 | $4,271 |
$1,576
30,485
kWh
|
$469
-
kW-mo/yr
|
- | $(-37.0) | |
03 | 2.7135: Install occupancy sensors | $297 | $264 |
$297
5,742
kWh
|
- | - | - | |
04 | 2.7134: Use photocell controls | $1,282 | $1,250 |
$1,282
24,796
kWh
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,460 | $100 |
$1,793
34,685
kWh
|
$507
-
kW-mo/yr
|
$(-600.0) | $(-240.0) | |
06 | 2.4151: Develop a repair/replace policy | $6,224 | $13,210 |
$4,358
84,294
kWh
|
$1,866
-
kW-mo/yr
|
- | - | |
07 | 2.7134: Use photocell controls | $4,207 | $15,472 |
$2,650
51,260
kWh
|
$1,557
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $15,959 | $36,057 |
$12,331
238,520
kWh
|
$4,505
-
kW-mo/yr
|
$(-600.0) | $(-277.0) | ||
TOTAL IMPLEMENTED | $11,752 | $20,585 |
$9,681
187,260
kWh
|
$2,948
-
kW-mo/yr
|
$(-600.0) | $(-277.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs