Assessment Year | 2012 |
---|---|
Principal Product | Ovens and ranges |
NAICS | 335210: Small Electrical Appliance Manufacturing |
SIC | 3634: Electric Housewares and Fans |
Sales Range | $100 M to 500M |
# of Employees | 664 |
Plant Area |
800,000
ft2
|
Annual Production | 600,000
pieces
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $949,163 | 18,641,100 |
kWh
|
$0.051 |
Electricity Demand | $587,103 | 60,394 |
kW-mo/yr
|
$9.72 |
Natural Gas | $216,499 | 32,705 |
MMBtu
|
$6.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $53,115 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,183 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $39,096 | $50,000 |
$19,716
377,555
kWh
|
$19,380
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $883 | $1,560 |
$535
10,243
kWh
|
$348
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,300 | $10,168 |
$1,826
36,640
kWh
|
$1,474
-
kW-mo/yr
|
- | |
04 | 2.2437: Recover waste heat from equipment | $7,288 | $37,820 | - | - |
$7,288
-
MMBtu
|
|
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,027 | $6,500 |
$530
10,150
kWh
|
$497
-
kW-mo/yr
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,521 | $3,200 |
$799
15,302
kWh
|
$722
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $53,115 | $109,248 |
$23,406
449,890
kWh
|
$22,421
-
kW-mo/yr
|
$7,288
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,183 | $11,728 |
$2,361
46,883
kWh
|
$1,822
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs