Assessment Year 2011
Principal Product Carpet
NAICS 314110: Carpet and Rug Mills
SIC 2273: Carpets and Rugs
Sales Range $10
M
to 50
M
# of Employees 350
Plant Area 600,000
ft2
Annual Production 9,000
thousand feet
Production Hrs. Annual 6,600
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $868,049 18,348,445
kWh
Electricity Demand $485,246 43,133
kW-mo/yr
Electricity Fees $40,700 -
Natural Gas $604,738 102,849
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $182,527 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $179,177

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $157,713 $165,618 $113,029
2,184,554
kWh
$44,684
-
kW-mo/yr
- - -
02 2.4151: Develop a repair/replace policy $15,127 $20,158 $10,738
207,539
kWh
$4,389
-
kW-mo/yr
- - -
03 2.2136: Install / repair insulation on steam lines $3,350 $800 - - $3,350
-
MMBtu
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,025 $500 $2,770
53,544
kWh
$1,095
-
kW-mo/yr
- $(-600.0) $(-240.0)
05 2.2614: Use cooling tower or economizer to replace chiller cooling $3,312 $8,420 $2,373
45,870
kWh
$939
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $182,527 $195,496 $128,910
2,491,507
kWh
$51,107
-
kW-mo/yr
$3,350
-
MMBtu
$(-600.0) $(-240.0)
TOTAL IMPLEMENTED $179,177 $194,696 $128,910
2,491,507
kWh
$51,107
-
kW-mo/yr
- $(-600.0) $(-240.0)
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs