Assessment Year | 2011 |
---|---|
Principal Product | Commercial refrigerated cases |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3444: Sheet Metal Work |
Sales Range | $100 M to 500M |
# of Employees | 800 |
Plant Area |
520,000
ft2
|
Annual Production | 40,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $583,249 | 17,674,200 |
kWh
|
$0.033 |
Electricity Demand | $433,037 | 32,220 |
kW-mo/yr
|
$13.44 |
Electricity Fees | $1,611 | - |
|
- |
Natural Gas | $387,304 | 54,732 |
MMBtu
|
$7.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $119,972 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $94,548 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $81,541 | $230,949 |
$49,404
1,364,400
kWh
|
$36,676
-
kW-mo/yr
|
- | - | $(-4,539.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,215 | $1,403 |
$348
9,620
kWh
|
$867
-
kW-mo/yr
|
- | - | - | |
03 | 2.2437: Recover waste heat from equipment | $7,463 | $10,818 | - | - |
$7,463
-
MMBtu
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,299 | $50 |
$4,809
132,803
kWh
|
$2,490
-
kW-mo/yr
|
- | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,334 | $100 |
$2,091
57,740
kWh
|
$1,083
-
kW-mo/yr
|
- | $(-600.0) | $(-240.0) | |
06 | 2.7425: Clean or color roof to reduce solar load | $17,685 | $29,025 |
$6,979
192,751
kWh
|
$10,706
-
kW-mo/yr
|
- | - | - | |
07 | 2.4151: Develop a repair/replace policy | $2,159 | $3,999 |
$1,239
34,225
kWh
|
$920
-
kW-mo/yr
|
- | - | - | |
08 | 2.7124: Make a practice of turning off lights when not needed | $276 | - |
$99
2,723
kWh
|
$177
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $119,972 | $276,344 |
$64,969
1,794,262
kWh
|
$52,919
-
kW-mo/yr
|
$7,463
-
MMBtu
|
$(-600.0) | $(-4,779.0) | ||
TOTAL IMPLEMENTED | $94,548 | $236,501 |
$57,891
1,598,788
kWh
|
$42,036
-
kW-mo/yr
|
- | $(-600.0) | $(-4,779.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs