Assessment Year | 2009 |
---|---|
Principal Product | Medium voltage protection equipment |
NAICS | 335313: Switchgear and Switchboard Apparatus Manufacturing |
SIC | 3613: Switchgear and Switchboard Apparatus |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
39,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $63,282 | 1,603,032 |
kWh
|
$0.039 |
Electricity Demand | $27,393 | 3,977 |
kW-mo/yr
|
$6.89 |
Natural Gas | $9,980 | 775 |
MMBtu
|
$12.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,328 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,569 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8112: Combine utility meters | $2,054 | - |
$2,054
-
kWh
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,357 | $500 |
$1,345
36,982
kWh
|
$1,012
-
kW-mo/yr
|
- | - | |
03 | 2.2437: Recover waste heat from equipment | $1,705 | $1,900 | - | - |
$1,705
-
MMBtu
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $210 | - |
$238
6,537
kWh
|
$72
-
kW-mo/yr
|
- | $(-100.0) | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,555 | $9,880 |
$1,583
43,542
kWh
|
$972
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $872 | $1,643 |
$539
14,829
kWh
|
$333
-
kW-mo/yr
|
- | - | |
07 | 2.7134: Use photocell controls | $213 | $200 |
$131
3,592
kWh
|
$82
-
kW-mo/yr
|
- | - | |
08 | 2.4151: Develop a repair/replace policy | $362 | $499 |
$224
6,172
kWh
|
$138
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $10,328 | $14,622 |
$6,114
111,654
kWh
|
$2,609
-
kW-mo/yr
|
$1,705
-
MMBtu
|
$(-100.0) | ||
TOTAL IMPLEMENTED | $6,569 | $12,722 |
$4,060
111,654
kWh
|
$2,609
-
kW-mo/yr
|
- | $(-100.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs