Assessment Year | 2007 |
---|---|
Principal Product | Shopping carts |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
300,000
ft2
|
Annual Production | 260,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $99,824 | 2,047,200 |
kWh
|
$0.049 |
Electricity Demand | $75,980 | 7,015 |
kW-mo/yr
|
$10.83 |
Electricity Fees | $2,654 | - |
|
- |
Natural Gas | $230,435 | 18,518 |
MMBtu
|
$12.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $62,162 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $37,329 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7314: Reduce ventilation air | $11,968 | $28,000 |
$(-634.0)
(-15,365)
kWh
|
$(-338.0)
-
kW-mo/yr
|
$13,500
-
MMBtu
|
- | $(-560.0) | |
02 | 2.4226: Use / purchase optimum sized compressor | $11,898 | $7,000 |
$7,314
177,227
kWh
|
$4,584
-
kW-mo/yr
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,542 | $100 |
$1,930
46,771
kWh
|
$1,212
-
kW-mo/yr
|
- | $(-300.0) | $(-300.0) | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $24,833 | $71,577 |
$17,356
420,552
kWh
|
$10,892
-
kW-mo/yr
|
- | - | $(-3,415.0) | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,788 | $50 |
$2,941
91,280
kWh
|
$1,847
-
kW-mo/yr
|
- | - | - | |
06 | 2.3212: Optimize plant power factor | $6,133 | $12,000 | - |
$6,133
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $62,162 | $118,727 |
$28,907
720,465
kWh
|
$24,330
-
kW-mo/yr
|
$13,500
-
MMBtu
|
$(-300.0) | $(-4,275.0) | ||
TOTAL IMPLEMENTED | $37,329 | $47,150 |
$11,551
299,913
kWh
|
$13,438
-
kW-mo/yr
|
$13,500
-
MMBtu
|
$(-300.0) | $(-860.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs