| Assessment Year | 2007 |
|---|---|
| Principal Product | Gas fired space heaters |
| NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
| SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
150,000
ft2
|
| Annual Production | 80,000
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $156,188 | 3,429,939 |
kWh
|
$0.046 |
| Electricity Fees | $36,902 | - |
|
- |
| Natural Gas | $157,898 | 12,942 |
MMBtu
|
$12.20 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,799 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,084 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $3,715 | $41,600 |
$(-1,043.0)
(-22,917)
kWh
|
$4,758
-
MMBtu
|
- | - | |
| 02 | 2.4151: Develop a repair/replace policy | $496 | $610 |
$496
10,908
kWh
|
- | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,232 | $100 |
$2,132
46,869
kWh
|
- | $(-600.0) | $(-300.0) | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $356 | $718 |
$356
7,818
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $5,799 | $43,028 |
$1,941
42,678
kWh
|
$4,758
-
MMBtu
|
$(-600.0) | $(-300.0) | ||
| TOTAL IMPLEMENTED | $2,084 | $1,428 |
$2,984
65,595
kWh
|
- | $(-600.0) | $(-300.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs