Assessment Year | 2006 |
---|---|
Principal Product | Mirrors |
NAICS | 327215: Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
176,000
ft2
|
Annual Production | 10,000
thousand feet
|
Production Hrs. Annual | 1,600
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $40,258 | 1,518,000 |
kWh
|
$0.027 |
Electricity Demand | $95,607 | 9,992 |
kW-mo/yr
|
$9.57 |
Electricity Fees | $1,536 | - |
|
- |
Natural Gas | $50,944 | 4,839 |
MMBtu
|
$10.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,053 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,861 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.131: Modify process to reduce material use/cost | $20,000 | $4,500 | - | - | - | - | $20,000 | |
02 | 2.2437: Recover waste heat from equipment | $21,192 | $1,000 | - | - |
$21,192
-
MMBtu
|
- | - | |
03 | 2.4151: Develop a repair/replace policy | $244 | $248 |
$57
2,160
kWh
|
$187
-
kW-mo/yr
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $752 | $500 |
$212
7,997
kWh
|
$540
-
kW-mo/yr
|
- | - | - | |
05 | 2.7124: Make a practice of turning off lights when not needed | $398 | $100 |
$398
14,998
kWh
|
- | - | - | - | |
06 | 2.2136: Install / repair insulation on steam lines | $67 | $147 | - | - |
$67
-
MMBtu
|
- | - | |
07 | 4.126: Install sensors to detect defects | $1,400 | $1,000 | - | - | - | $200 | $1,200 | |
TOTAL RECOMMENDED | $44,053 | $7,495 |
$667
25,155
kWh
|
$727
-
kW-mo/yr
|
$21,259
-
MMBtu
|
$200 | $21,200 | ||
TOTAL IMPLEMENTED | $2,861 | $1,995 |
$667
25,155
kWh
|
$727
-
kW-mo/yr
|
$67
-
MMBtu
|
$200 | $1,200 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs