Assessment Year | 2003 |
---|---|
Principal Product | recycled paper products |
NAICS | 322121: Paper (except Newsprint) Mills |
SIC | 2621: Paper Mills |
Sales Range | $10 M to 50M |
# of Employees | 128 |
Plant Area |
250,000
ft2
|
Annual Production | 100,000,000
lb
|
Production Hrs. Annual | 8,600
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,681,194 | 61,061,782 |
kWh
|
$0.028 |
Electricity Demand | $1,455,043 | 98,402 |
kW-mo/yr
|
$14.79 |
Electricity Fees | $(-188,269.0) | - |
|
- |
Natural Gas | $1,899,050 | 308,413 |
MMBtu
|
$6.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $261,694 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $174,307 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $149,890 | $50,000 | - | - |
$149,890
-
MMBtu
|
- | - | - | |
02 | 3.4113: Treat and reuse rinse waters | $71,629 | $300,000 |
$(-18,494.0)
(-671,794)
kWh
|
$(-14,077.0)
-
kW-mo/yr
|
- |
$109,200
-
Tgal
|
- | $(-5,000.0) | |
03 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $15,758 | $45,000 |
$(-3,859.0)
(-140,160)
kWh
|
$(-2,883.0)
-
kW-mo/yr
|
- | - |
$24,500
-
lb
|
$(-2,000.0) | |
04 | 2.1133: Adjust burners for efficient operation | $16,620 | $1,000 | - | - |
$16,620
-
MMBtu
|
- | - | - | |
05 | 2.4226: Use / purchase optimum sized compressor | $4,551 | - |
$4,551
179,040
kWh
|
- | - | - | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,246 | $2,400 |
$1,840
66,829
kWh
|
$1,406
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $261,694 | $398,400 |
$(-15,962.0)
(-566,085)
kWh
|
$(-15,554.0)
-
kW-mo/yr
|
$166,510
-
MMBtu
|
$109,200
-
Tgal
|
$24,500
-
lb
|
$(-7,000.0) | ||
TOTAL IMPLEMENTED | $174,307 | $53,400 |
$6,391
245,869
kWh
|
$1,406
-
kW-mo/yr
|
$166,510
-
MMBtu
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs