| Assessment Year | 2002 |
|---|---|
| Principal Product | Lumber |
| NAICS |
n/a
|
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $10 M to 50M |
| # of Employees | 95 |
| Plant Area |
150,000
ft2
|
| Annual Production | 70,000
thousand feet
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | South Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $389,985 | 7,308,573 |
kWh
|
$0.053 |
| Electricity Demand | $160,196 | 33,584 |
kW-mo/yr
|
$4.77 |
| Electricity Fees | $14,781 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $25,824 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,534 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Personnel Changes Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $1,684 | $6,000 |
$2,185
41,950
kWh
|
$938
-
kW-mo/yr
|
$(-1,439.0)
-
Tgal
|
- | - | |
| 02 | 2.4151: Develop a repair/replace policy | $4,419 | $8,200 |
$2,876
53,903
kWh
|
$1,543
-
kW-mo/yr
|
- | - | - | |
| 03 | 3.1191: Change procedures / equipment / operating conditions | $19,606 | $550 | - | - | - | $(-3,750.0) | $23,356 | |
| 04 | 2.7134: Use photocell controls | $115 | $260 |
$75
1,400
kWh
|
$40
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $25,824 | $15,010 |
$5,136
97,253
kWh
|
$2,521
-
kW-mo/yr
|
$(-1,439.0)
-
Tgal
|
$(-3,750.0) | $23,356 | ||
| TOTAL IMPLEMENTED | $4,534 | $8,460 |
$2,951
55,303
kWh
|
$1,583
-
kW-mo/yr
|
- | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs