ITAC Assessment: NC0230
ITAC logo
ITAC Assessment: NC0230
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2002
Principal Product Household textile goods
NAICS
n/a
SIC 2392: House furnishing, Except Curtains and Draperies
Sales Range $10
M
to 50
M
# of Employees 145
Plant Area 130,000
ft2
Annual Production 1,200,000
lb
Production Hrs. Annual 2,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $76,506 1,666,800
kWh
Electricity Demand $36,206 7,404
kW-mo/yr
Electricity Fees $252 -
Natural Gas $73,266 73,073
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,701 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,096

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings
01 2.3134: Shift from daytime to nighttime operation $22,396 $5,000 - $4,020
-
kW-mo/yr
$26,376 - $(-8,000.0)
02 2.4151: Develop a repair/replace policy $1,099 $1,354 $663
13,372
kWh
$436
-
kW-mo/yr
- - -
03 2.2437: Recover waste heat from equipment $893 $500 - - - $893
-
MMBtu
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $1,301 $2,500 $1,058
21,340
kWh
$243
-
kW-mo/yr
- - -
05 2.7131: Add area lighting switches $1,053 $3,340 $661
13,340
kWh
$392
-
kW-mo/yr
- - -
06 2.7111: Reduce illumination to minimum necessary levels $797 $1,040 $501
10,098
kWh
$296
-
kW-mo/yr
- - -
07 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $645 $1,100 $296
5,973
kWh
$349
-
kW-mo/yr
- - -
08 2.7231: Use radiant heater for spot heating $263 - - - - $263
-
MMBtu
-
09 2.1114: Limit and control secondary combustion air in furnace $4,254 $3,500 - - - $4,254
-
MMBtu
-
TOTAL RECOMMENDED $32,701 $18,334 $3,179
64,123
kWh
$5,736
-
kW-mo/yr
$26,376 $5,410
-
MMBtu
$(-8,000.0)
TOTAL IMPLEMENTED $8,096 $9,734 $1,825
36,810
kWh
$1,124
-
kW-mo/yr
- $5,147
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs