Assessment Year | 2002 |
---|---|
Principal Product | Household textile goods |
NAICS |
n/a
|
SIC | 2392: House furnishing, Except Curtains and Draperies |
Sales Range | $10 M to 50M |
# of Employees | 145 |
Plant Area |
130,000
ft2
|
Annual Production | 1,200,000
lb
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $76,506 | 1,666,800 |
kWh
|
$0.046 |
Electricity Demand | $36,206 | 7,404 |
kW-mo/yr
|
$4.89 |
Electricity Fees | $252 | - |
|
- |
Natural Gas | $73,266 | 73,073 |
MMBtu
|
$1.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,701 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,096 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3134: Shift from daytime to nighttime operation | $22,396 | $5,000 | - |
$4,020
-
kW-mo/yr
|
$26,376 | - | $(-8,000.0) | |
02 | 2.4151: Develop a repair/replace policy | $1,099 | $1,354 |
$663
13,372
kWh
|
$436
-
kW-mo/yr
|
- | - | - | |
03 | 2.2437: Recover waste heat from equipment | $893 | $500 | - | - | - |
$893
-
MMBtu
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,301 | $2,500 |
$1,058
21,340
kWh
|
$243
-
kW-mo/yr
|
- | - | - | |
05 | 2.7131: Add area lighting switches | $1,053 | $3,340 |
$661
13,340
kWh
|
$392
-
kW-mo/yr
|
- | - | - | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $797 | $1,040 |
$501
10,098
kWh
|
$296
-
kW-mo/yr
|
- | - | - | |
07 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $645 | $1,100 |
$296
5,973
kWh
|
$349
-
kW-mo/yr
|
- | - | - | |
08 | 2.7231: Use radiant heater for spot heating | $263 | - | - | - | - |
$263
-
MMBtu
|
- | |
09 | 2.1114: Limit and control secondary combustion air in furnace | $4,254 | $3,500 | - | - | - |
$4,254
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $32,701 | $18,334 |
$3,179
64,123
kWh
|
$5,736
-
kW-mo/yr
|
$26,376 |
$5,410
-
MMBtu
|
$(-8,000.0) | ||
TOTAL IMPLEMENTED | $8,096 | $9,734 |
$1,825
36,810
kWh
|
$1,124
-
kW-mo/yr
|
- |
$5,147
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs