Assessment Year | 2001 |
---|---|
Principal Product | Dyed woven fabrics |
NAICS |
n/a
|
SIC | 2269: Finishers of Textiles, Not elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 300 |
Plant Area |
750,000
ft2
|
Annual Production | 750,000
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $523,100 | 5,587,630 |
kWh
|
$0.094 |
Electricity Demand | $382,459 | 40,800 |
kW-mo/yr
|
$9.37 |
Electricity Fees | $9,657 | - |
|
- |
Natural Gas | $1,969,268 | 270,951 |
MMBtu
|
$7.27 |
Coal | $1,000,000 | 487,805 |
MMBtu
|
$2.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $121,927 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $74,182 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Coal Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4151: Develop a repair/replace policy | $2,783 | $1,895 |
$1,649
60,189
kWh
|
$1,134
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,625 | $33,848 |
$9,259
337,914
kWh
|
$6,366
-
kW-mo/yr
|
- | - | - | |
03 | 2.4156: Establish a preventative maintenance program | $27,745 | $33,990 | n/a |
$6,028
220,000
kWh
|
$6,217
-
kW-mo/yr
|
- | $10,000 | $5,500 |
04 | 2.1115: Eliminate combustible gas in flue gas | $15,365 | $5,000 | - | - |
$15,365
-
MMBtu
|
- | - | |
05 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $20,000 | $40,000 | n/a |
$964
35,200
kWh
|
$668
-
kW-mo/yr
|
$18,368
-
MMBtu
|
- | - |
06 | 2.1232: Keep boiler tubes clean | $3,649 | $13,000 | - | - |
$3,649
-
MMBtu
|
- | - | |
07 | 2.2135: Repair and eliminate steam leaks | $8,655 | $3,500 | - | - |
$8,655
-
MMBtu
|
- | - | |
08 | 2.2414: Use waste heat from hot flue gases to preheat | $28,105 | $100,000 | - | - |
$28,105
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $121,927 | $231,233 |
$17,900
653,303
kWh
|
$14,385
-
kW-mo/yr
|
$74,142
-
MMBtu
|
$10,000 | $5,500 | ||
TOTAL IMPLEMENTED | $74,182 | $157,243 |
$10,908
398,103
kWh
|
$7,500
-
kW-mo/yr
|
$55,774
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Coal Savings | Administrative Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs