Assessment Year 2001
Principal Product Textile dyes
NAICS
n/a
SIC 2816: Inorganic Pigments
Sales Range $5
M
to 10
M
# of Employees 60
Plant Area 150,000
ft2
Annual Production 14,000,000
lb
Production Hrs. Annual 8,400
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $128,785 4,994,400
kWh
Electricity Demand $90,945 9,584
kW-mo/yr
Electricity Fees $7,747 -
Natural Gas $96,002 13,282
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $169,660 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings Personnel Changes Savings
01 2.1133: Adjust burners for efficient operation $1,737 $800 n/a - - - $1,737
-
MMBtu
- -
02 2.2163: Use minimum steam operating pressure $732 $75 n/a - - - $732
-
MMBtu
- -
03 2.8123: Pay utility bills on time $1,132 $500 n/a - - $618 $371
-
MMBtu
$143
-
Tgal
-
04 2.4239: Eliminate or reduce compressed air usage $5,303 $8,000 n/a $3,494
134,000
kWh
$1,809
-
kW-mo/yr
- - - -
05 2.3113: Make ice during off peak hours for cooling $18,934 $80,000 n/a $5,256
(-92,400)
kWh
$13,678
-
kW-mo/yr
- - - -
06 4.446: Automate finishing process $141,822 $120,500 n/a $12,617
485,275
kWh
$6,530
-
kW-mo/yr
- - $(-3,325.0)
-
Tgal
$126,000
TOTAL RECOMMENDED $169,660 $209,875 $21,367
526,875
kWh
$22,017
-
kW-mo/yr
$618 $2,840
-
MMBtu
$(-3,182.0)
-
Tgal
$126,000
TOTAL IMPLEMENTED - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs