Assessment Year | 2000 |
---|---|
Principal Product | Denim weaving |
NAICS |
n/a
|
SIC | 2210: |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
250,000
ft2
|
Annual Production | 1,300
thousand feet
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $515,447 | 17,186,694 |
kWh
|
$0.030 |
Electricity Demand | $240,016 | 29,725 |
kW-mo/yr
|
$8.07 |
Electricity Fees | $31,379 | - |
|
- |
Natural Gas | $378,143 | 86,426 |
MMBtu
|
$4.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $66,364 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $6,613 | $1,000 | n/a |
$2,665
88,804
kWh
|
$3,948
-
kW-mo/yr
|
- | - | - | - | - |
02 | 2.4221: Install compressor air intakes in coolest locations | $7,579 | $20,000 | n/a |
$4,135
137,749
kWh
|
$3,444
-
kW-mo/yr
|
- | - | - | - | - |
03 | 2.7241: Install outside air damper / economizer on hvac unit | $15,232 | $20,000 | n/a |
$15,232
507,913
kWh
|
- | - | - | - | - | - |
04 | 4.641: Eliminate shutdowns of controls due to overheating | $11,092 | $16,250 | n/a |
$339
11,430
kWh
|
$501
-
kW-mo/yr
|
- |
$(-243.0)
-
Tgal
|
- | - | $10,495 |
05 | 2.1133: Adjust burners for efficient operation | $10,548 | $2,000 | n/a | - | - |
$10,548
-
MMBtu
|
- | - | - | - |
06 | 4.611: Begin a practice of predictive / preventative maintenance | $15,300 | $200 | n/a | - | - | - | - | $15,000 | $300 | - |
TOTAL RECOMMENDED | $66,364 | $59,450 |
$22,371
745,896
kWh
|
$7,893
-
kW-mo/yr
|
$10,548
-
MMBtu
|
$(-243.0)
-
Tgal
|
$15,000 | $300 | $10,495 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs