Assessment Year | 2000 |
---|---|
Principal Product | Fabric for shirts and home fashion |
NAICS |
n/a
|
SIC | 2210: |
Sales Range | $100 M to 500M |
# of Employees | 680 |
Plant Area |
785,000
ft2
|
Annual Production | 35,000,000
pieces
|
Production Hrs. Annual | 8,448
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,884,815 | 122,808,912 |
kWh
|
$0.023 |
Electricity Demand | $2,744,407 | 180,881 |
kW-mo/yr
|
$15.17 |
Electricity Fees | $218,049 | - |
|
- |
Natural Gas | $505,889 | 120,209 |
MMBtu
|
$4.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $89,348 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,527 | $2,233 |
$828
35,170
kWh
|
$699
-
kW-mo/yr
|
- | |
02 | 2.3132: Recharge batteries on during off-peak demand periods | $824 | - | - |
$824
-
kW-mo/yr
|
- | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $56,972 | $10,000 |
$21,482
907,972
kWh
|
$35,490
-
kW-mo/yr
|
- | |
04 | 2.4224: Upgrade controls on compressors | $24,065 | $105,600 |
$13,029
554,513
kWh
|
$11,036
-
kW-mo/yr
|
- | |
05 | 3.4114: Replace city water with recycled water via cooling tower | $5,960 | $2,500 | - | - |
$5,960
-
Tgal
|
|
TOTAL RECOMMENDED | $89,348 | $120,333 |
$35,339
1,497,655
kWh
|
$48,049
-
kW-mo/yr
|
$5,960
-
Tgal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs