ITAC Assessment: NC0103
ITAC logo
ITAC Assessment: NC0103
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Yarn
NAICS
n/a
SIC 2281: Yarn Spinning Mills
Sales Range $10
M
to 50
M
# of Employees 260
Plant Area 109,375
ft2
Annual Production 9,500,000
lb
Production Hrs. Annual 8,760
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $778,267 20,672,333
kWh
Electricity Demand $510,363 35,280
kW-mo/yr
Electricity Fees $38,659 -
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $30,769 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $25,919

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
01 2.4133: Use most efficient type of electric motors $13,500 $6,167 $8,852
235,346
kWh
$4,648
-
kW-mo/yr
-
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,267 $2,925 $1,267
33,705
kWh
- -
03 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $3,391 $5,000 $2,134
56,565
kWh
$1,257
-
kW-mo/yr
-
04 2.4221: Install compressor air intakes in coolest locations $1,152 $350 $755
19,930
kWh
$397
-
kW-mo/yr
-
05 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $3,167 $530 $2,037
54,220
kWh
$1,130
-
kW-mo/yr
-
06 2.4239: Eliminate or reduce compressed air usage $8,100 $10,000 $5,309
140,973
kWh
$2,791
-
kW-mo/yr
-
07 3.5315: Lease / purchase baler; sell cardboard to recycler $192 $100 - - $192
-
lb
TOTAL RECOMMENDED $30,769 $25,072 $20,354
540,739
kWh
$10,223
-
kW-mo/yr
$192
-
lb
TOTAL IMPLEMENTED $25,919 $17,047 $16,953
450,469
kWh
$8,966
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs