Assessment Year | 1996 |
---|---|
Principal Product | Boxes |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
120,000
ft2
|
Annual Production | 50,000,000
pieces
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $35,829 | 1,092,321 |
kWh
|
$0.033 |
Electricity Demand | $27,545 | 3,299 |
kW-mo/yr
|
$8.35 |
Electricity Fees | $2,551 | - |
|
- |
Natural Gas | $27,996 | 5,197 |
MMBtu
|
$5.39 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $50,763 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,021 | $2,451 |
$1,744
53,048
kWh
|
$1,277
-
kW-mo/yr
|
- | - | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $138 | $700 |
$65
2,052
kWh
|
$23
-
kW-mo/yr
|
- | - | - | - | $50 | |
03 | 2.4133: Use most efficient type of electric motors | $469 | $772 |
$286
8,792
kWh
|
$183
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $486 | $245 |
$302
9,086
kWh
|
$184
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.7313: Recycle air for heating, ventilation and air conditioning | $11,779 | $11,650 | - | - |
$11,779
-
MMBtu
|
- | - | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $488 | $210 |
$303
9,086
kWh
|
$185
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 3.5313: Increase amount of waste recovered for resale | $657 | $100 | - | - | - |
$657
-
lb
|
- | - | - | |
08 | 4.444: Install system to collect scrap | $20,250 | $1,000 | - | - | - | - | $20,250 | - | - | |
09 | 4.511: Expand operations into unused space | $13,475 | - |
$745
22,860
kWh
|
$451
-
kW-mo/yr
|
$1,011
-
MMBtu
|
- | - | $11,268 | - | |
TOTAL RECOMMENDED | $50,763 | $17,128 |
$3,445
104,924
kWh
|
$2,303
-
kW-mo/yr
|
$12,790
-
MMBtu
|
$657
-
lb
|
$20,250 | $11,268 | $50 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs