ITAC Assessment: NC0077
ITAC logo
ITAC Assessment: NC0077
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1996
Principal Product Fabricated metal parts
NAICS
n/a
SIC 3499: Fabricated Metal Products, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 62
Plant Area 47,225
ft2
Annual Production 10,000,000
lb
Production Hrs. Annual 2,000
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $39,950 822,685
kWh
Electricity Demand $25,050 3,000
kW-mo/yr
Natural Gas $8,496 1,717
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $18,054 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,053

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (haz) Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,351 $2,860 $579
17,292
kWh
$772
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $132 $840 $98
2,931
kWh
$34
-
kW-mo/yr
- -
03 2.4239: Eliminate or reduce compressed air usage $278 $210 $185
5,569
kWh
$93
-
kW-mo/yr
- -
04 2.4221: Install compressor air intakes in coolest locations $544 $160 $317
9,672
kWh
$227
-
kW-mo/yr
- -
05 2.4226: Use / purchase optimum sized compressor $775 - $775
28,429
kWh
- - -
06 2.2511: Insulate bare equipment $306 $100 $188
7,034
kWh
$118
-
kW-mo/yr
- -
07 2.1311: Replace electrically-operated equipment with fossil fuel equipment $4,818 $5,000 $2,849
72,392
kWh
$3,637
-
kW-mo/yr
$(-1,668.0)
-
MMBtu
-
08 3.2123: Convert to high volume low pressure (hvlp) paint guns $9,850 $1,800 - - - $9,850
-
lb
TOTAL RECOMMENDED $18,054 $10,970 $4,991
143,319
kWh
$4,881
-
kW-mo/yr
$(-1,668.0)
-
MMBtu
$9,850
-
lb
TOTAL IMPLEMENTED $1,053 $210 $960
33,998
kWh
$93
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs