| Assessment Year | 1995 |
|---|---|
| Principal Product | Milk and Ice Cream |
| NAICS |
n/a
|
| SIC | 2026: Fluid Milk |
| Sales Range | $50 M to 100M |
| # of Employees | 52 |
| Plant Area |
60,000
ft2
|
| Annual Production | 12,500
Tgal
|
| Production Hrs. Annual | 3,200
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $479,852 | 5,848,183 |
kWh
|
$0.082 |
| Natural Gas | $61,000 | 10,683 |
MMBtu
|
$5.71 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $85,718 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $85,236 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,682 | $546 |
$4,682
74,150
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,267 | $1,710 |
$2,267
19,050
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $482 | $1,680 |
$482
5,862
kWh
|
|
| 04 | 2.2624: Use cold waste water to cool chiller feed water | $5,067 | $8,000 |
$5,067
59,789
kWh
|
|
| 05 | 2.3192: Use fossil fuel powered generator during peak demand periods | $72,500 | $170,000 |
$72,500
-
kWh
|
|
| 06 | 2.4221: Install compressor air intakes in coolest locations | $720 | $200 |
$720
6,155
kWh
|
|
| TOTAL RECOMMENDED | $85,718 | $182,136 |
$85,718
165,006
kWh
|
||
| TOTAL IMPLEMENTED | $85,236 | $180,456 |
$85,236
159,144
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs