Assessment Year | 1994 |
---|---|
Principal Product | Membrane roofing |
NAICS |
n/a
|
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 325 |
Plant Area |
237,000
ft2
|
Annual Production | 10,000
thousand feet
|
Production Hrs. Annual | 4,200
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $580,722 | 10,988,570 |
kWh
|
$0.053 |
Natural Gas | $84,069 | 30,600 |
MMBtu
|
$2.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,072 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $494 | $360 |
$494
9,379
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $13,656 | $28,570 |
$13,656
257,620
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,535 | $4,662 |
$1,535
29,015
kWh
|
- | |
04 | 2.1213: Direct warmest air to combustion intake | $420 | $300 | - |
$420
-
MMBtu
|
|
05 | 2.2511: Insulate bare equipment | $4,967 | $536 | - |
$4,967
-
MMBtu
|
|
TOTAL RECOMMENDED | $21,072 | $34,428 |
$15,685
296,014
kWh
|
$5,387
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs