Assessment Year 1993
Principal Product FIber Drums and Boxes
NAICS
n/a
SIC 2655: Fiber Cans, Tubes, Drums, and Similar Products
Sales Range $5
M
to 10
M
# of Employees 92
Plant Area 121,600
ft2
Annual Production 0
units
Production Hrs. Annual 4,750
hrs
Location (State) North Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $108,762 1,687,573
kWh
Natural Gas $7,483 1,449
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $33,938 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $17,038

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,616 $330 $2,616
40,152
kWh
02 2.4221: Install compressor air intakes in coolest locations $701 $350 $701
10,844
kWh
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $428 $1,594 $428
6,741
kWh
04 2.4133: Use most efficient type of electric motors $4,244 $6,030 $4,244
65,358
kWh
05 2.2511: Insulate bare equipment $2,234 $50 $2,234
41,911
kWh
06 2.7142: Utilize higher efficiency lamps and/or ballasts $10,422 $1,935 $10,422
160,317
kWh
07 2.7111: Reduce illumination to minimum necessary levels $13,293 $3,900 $13,293
204,572
kWh
TOTAL RECOMMENDED $33,938 $14,189 $33,938
529,895
kWh
TOTAL IMPLEMENTED $17,038 $6,174 $17,038
262,309
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings