Assessment Year | 1993 |
---|---|
Principal Product | Furniture |
NAICS |
n/a
|
SIC | 2511: Wood Household Furniture, Except Upholstered |
Sales Range | $10 M to 50M |
# of Employees | 268 |
Plant Area |
248,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,310
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $193,925 | 3,679,074 |
kWh
|
$0.053 |
Natural Gas | $1,292 | 125 |
MMBtu
|
$10.34 |
Fuel Oil #2 | $2,002 | 343 |
MMBtu
|
$5.84 |
Other Energy | $16,276 | 4,332 |
MMBtu
|
$3.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $53,294 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,349 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Wood Savings |
---|---|---|---|---|---|---|---|
01 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $16,854 | $32,000 |
$16,854
172,333
kWh
|
- | - | |
02 | 2.2437: Recover waste heat from equipment | $3,805 | $6,000 | - |
$3,805
-
MMBtu
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,206 | $1,590 |
$1,206
22,860
kWh
|
- | - | |
04 | 2.4239: Eliminate or reduce compressed air usage | $4,580 | - |
$4,580
86,460
kWh
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $770 | $450 |
$770
14,654
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,702 | $10,980 |
$10,702
201,934
kWh
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,177 | $2,106 |
$2,177
41,032
kWh
|
- | - | |
08 | 2.1222: Install turbulators | $8,700 | $1,500 | - | - |
$8,700
-
MMBtu
|
|
09 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,500 | $200 |
$4,500
-
kWh
|
- | - | |
TOTAL RECOMMENDED | $53,294 | $54,826 |
$40,789
539,273
kWh
|
$3,805
-
MMBtu
|
$8,700
-
MMBtu
|
||
TOTAL IMPLEMENTED | $22,349 | $15,036 |
$13,649
257,620
kWh
|
- |
$8,700
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings | Wood Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs