Assessment Year | 1993 |
---|---|
Principal Product | Automotive Steering Part |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 135 |
Plant Area |
139,800
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $376,036 | 6,945,194 |
kWh
|
$0.054 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,604 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,399 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7134: Use photocell controls | $381 | $159 |
$381
7,034
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $648 | $360 |
$648
12,016
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,625 | $300 |
$5,625
103,458
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $2,844 | $1,000 |
$2,844
52,169
kWh
|
- | |
05 | 2.2437: Recover waste heat from equipment | $6,594 | $6,000 |
$6,594
322,098
kWh
|
- | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $13,205 | $31,000 |
$18,605
342,028
kWh
|
$(-5,400.0)
-
MMBtu
|
|
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $307 | $650 |
$307
5,569
kWh
|
- | |
TOTAL RECOMMENDED | $29,604 | $39,469 |
$35,004
844,372
kWh
|
$(-5,400.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,399 | $8,469 |
$16,399
502,344
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs