ITAC Assessment: MZ0364
ITAC logo
ITAC Assessment: MZ0364
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Large advertising signs
NAICS 339950: Sign Manufacturing
SIC 3993: Signs and Advertising Specialties
Sales Range $50
M
to 100
M
# of Employees 157
Plant Area 147,500
ft2
Annual Production 17,500
pieces
Production Hrs. Annual 5,880
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $193,409 1,869,619
kWh
Natural Gas $70,020 5,854
MMBtu
Waste Disposal Costs
Water Usage $2,807 390
Tgal
Water Disposal $1,751 390
Tgal
TOTAL YEARLY COSTS $267,987
RECOMMENDED SAVINGS* $54,256 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings One-time Revenue or Avoided Cost Savings
01 2.7135: Install occupancy sensors $5,079 $9,499 $5,079
50,781
kWh
-
02 2.4239: Eliminate or reduce compressed air usage $1,335 $2,050 $1,335
13,349
kWh
-
03 2.9114: Use solar heat to make electricty $42,019 $292,428 $42,019
420,194
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,943 $7,560 $1,212
12,120
kWh
$731
05 2.7135: Install occupancy sensors $1,125 $1,100 $1,125
11,256
kWh
-
06 2.4221: Install compressor air intakes in coolest locations $496 $2,600 $496
4,976
kWh
-
07 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,259 $5,474 $2,259
22,590
kWh
-
TOTAL RECOMMENDED $54,256 $320,711 $53,525
535,266
kWh
$731
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs