Assessment Year | 2022 |
---|---|
Principal Product | performance material fabric for filters |
NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $10 M to 50M |
# of Employees | 57 |
Plant Area |
51,000
ft2
|
Annual Production | 24,600,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $379,853 | 7,364,222 |
kWh
|
$0.052 | |
Electricity Demand | $179,605 | 15,414 |
kW-mo/yr
|
$11.65 | |
Natural Gas | $293,478 | 87,116 |
MMBtu
|
$3.37 | |
Waste Disposal Costs | |||||
Water Usage | $9,091 | 1,510 |
Tgal
|
$6.02 | |
Water Disposal | $9,455 | 1,510 |
Tgal
|
$6.26 | |
TOTAL YEARLY COSTS | $871,482 | ||||
RECOMMENDED SAVINGS* | $119,909 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $8,506 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $558 | $480 |
$558
10,737
kWh
|
- | |
02 | 2.2437: Recover waste heat from equipment | $4,654 | $7,600 |
$4,654
89,507
kWh
|
- | |
03 | 2.2511: Insulate bare equipment | $1,834 | $680 |
$1,834
35,263
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $701 | $1,200 |
$701
13,482
kWh
|
- | |
05 | 2.9114: Use solar heat to make electricty | $106,813 | $957,388 |
$74,659
1,435,760
kWh
|
$32,154
-
kW-mo/yr
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $759 | $1,330 |
$524
10,080
kWh
|
$235
-
kW-mo/yr
|
|
07 | 2.4221: Install compressor air intakes in coolest locations | $4,141 | $9,100 |
$2,860
54,992
kWh
|
$1,281
-
kW-mo/yr
|
|
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $449 | $200 |
$310
5,965
kWh
|
$139
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $119,909 | $977,978 |
$86,100
1,655,786
kWh
|
$33,809
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $8,506 | $11,290 |
$8,271
159,069
kWh
|
$235
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs