Assessment Year 2022
Principal Product PVC pipe
NAICS 325211: Plastics Material and Resin Manufacturing
SIC 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers
Sales Range $50
M
to 100
M
# of Employees 31
Plant Area 60,000
ft2
Annual Production 70,000,000
lb
Production Hrs. Annual 8,160
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $281,301 5,575,128
kWh
Electricity Demand $196,242 9,214
kW-mo/yr
Natural Gas $81,541 41,115
MMBtu
Waste Disposal Costs
Water Usage $27,910 6,313
Tgal
Water Disposal $22,718 6,313
Tgal
TOTAL YEARLY COSTS $609,712
RECOMMENDED SAVINGS* $170,841 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $73,208

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $12,571 $18,580 $12,571
251,430
kWh
- - -
02 2.9114: Use solar heat to make electricty $87,851 $670,334 $48,600
972,004
kWh
$39,251
-
kW-mo/yr
- -
03 2.4221: Install compressor air intakes in coolest locations $1,554 $7,980 $971
18,678
kWh
$583
-
kW-mo/yr
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,676 $1,330 $582
11,642
kWh
$1,094
-
kW-mo/yr
- -
05 2.7135: Install occupancy sensors $506 $780 $506
10,118
kWh
- - -
06 2.1233: Analyze flue gas for proper air/fuel ratio $2,198 $720 - - $2,198
-
MMBtu
-
07 3.4116: Meter recycled water (to reduce sewer charges) $5,524 $7,544 - - - $5,524
-
Tgal
08 2.2622: Replace existing chiller with high efficiency model $58,961 $200,000 $32,847
656,939
kWh
$26,114
-
kW-mo/yr
- -
TOTAL RECOMMENDED $170,841 $907,268 $96,077
1,920,811
kWh
$67,042
-
kW-mo/yr
$2,198
-
MMBtu
$5,524
-
Tgal
TOTAL IMPLEMENTED $73,208 $219,910 $46,000
920,011
kWh
$27,208
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs