| Assessment Year | 2022 |
|---|---|
| Principal Product | industrial ball and roller bearings |
| NAICS | 332911: Industrial Valve Manufacturing |
| SIC | 3562: Ball and Roller Bearings |
| Sales Range | $50 M to 100M |
| # of Employees | 250 |
| Plant Area |
222,000
ft2
|
| Annual Production | 5,000,000
pieces
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $954,693 | 14,906,400 |
kWh
|
$0.064 | |
| Electricity Demand | $537,519 | 38,669 |
kW-mo/yr
|
$13.90 | |
| Natural Gas | $297,888 | 54,632 |
MMBtu
|
$5.45 | |
| Waste Disposal Costs | |||||
| Water Usage | $174,445 | 58,995 |
Tgal
|
$2.96 | |
| TOTAL YEARLY COSTS | $1,964,545 | ||||
| RECOMMENDED SAVINGS* | $544,473 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $407,900 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4239: Eliminate or reduce compressed air usage | $1,449 | $3,200 |
$1,449
22,643
kWh
|
- | - | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $4,611 | $4,700 |
$3,386
52,912
kWh
|
$1,225
-
kW-mo/yr
|
- | - | |
| 03 | 2.6127: Maintain air filters by cleaning or replacement | $1,085 | $144 |
$1,053
16,463
kWh
|
$32
-
kW-mo/yr
|
- | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $874 | $140 |
$642
10,025
kWh
|
$232
-
kW-mo/yr
|
- | - | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $18,930 | $12,076 |
$18,930
295,782
kWh
|
- | - | - | |
| 06 | 2.3212: Optimize plant power factor | $1,106 | $2,244 | - |
$1,106
-
kW-mo/yr
|
- | - | |
| 07 | 2.4113: Install motor voltage controller on lightly loaded motors | $597 | $580 |
$597
9,326
kWh
|
- | - | - | |
| 08 | 4.132: Purchase new equipment to reduce material use / cost | $116,541 | $552,315 |
$(-60,541.0)
(-945,964)
kWh
|
$(-21,870.0)
-
kW-mo/yr
|
- | $198,952 | |
| 09 | 2.2425: Use flue gases to heat process or service water | $10,442 | $18,650 | - | - |
$10,442
-
MMBtu
|
- | |
| 10 | 2.7144: Install spectral reflectors / delamp | $1,954 | $1,170 |
$1,282
20,030
kWh
|
$464
-
kW-mo/yr
|
- | $208 | |
| 11 | 2.9114: Use solar heat to make electricty | $384,733 | $2,868,753 |
$277,233
4,331,772
kWh
|
$107,500
-
kW-mo/yr
|
- | - | |
| 12 | 2.7221: Lower temperature during the winter season and vice-versa | $2,151 | $600 |
$1,579
24,670
kWh
|
$572
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $544,473 | $3,464,572 |
$245,610
3,837,659
kWh
|
$89,261
-
kW-mo/yr
|
$10,442
-
MMBtu
|
$199,160 | ||
| TOTAL IMPLEMENTED | $407,900 | $2,886,997 |
$299,262
4,675,986
kWh
|
$108,638
-
kW-mo/yr
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs