| Assessment Year | 2022 |
|---|---|
| Principal Product | Aluminum boats |
| NAICS | 336612: Boat Building |
| SIC | 3732: Boat Building and Repairing |
| Sales Range | $50 M to 100M |
| # of Employees | 477 |
| Plant Area |
365,727
ft2
|
| Annual Production | 20,000,000
lb
|
| Production Hrs. Annual | 5,000
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $441,333 | 6,101,840 |
kWh
|
$0.072 | |
| Electricity Demand | $170,438 | 20,163 |
kW-mo/yr
|
$8.45 | |
| Natural Gas | $490,460 | 43,587 |
MMBtu
|
$11.25 | |
| Waste Disposal Costs | |||||
| Water Usage | $3,021 | 787 |
Tgal
|
$3.84 | |
| Water Disposal | $4,850 | 787 |
Tgal
|
$6.16 | |
| TOTAL YEARLY COSTS | $1,110,102 | ||||
| RECOMMENDED SAVINGS* | $82,377 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $247 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4239: Eliminate or reduce compressed air usage | $15,617 | $50,190 |
$15,617
197,681
kWh
|
- | - | |
| 02 | 2.2425: Use flue gases to heat process or service water | $4,781 | $18,650 | - | - |
$4,781
-
MMBtu
|
|
| 03 | 2.2437: Recover waste heat from equipment | $35,350 | $30,500 | - | - |
$35,350
-
MMBtu
|
|
| 04 | 2.7135: Install occupancy sensors | $247 | $870 |
$247
3,411
kWh
|
- | - | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,459 | $17,421 |
$17,459
238,936
kWh
|
- | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $640 | $160 |
$500
6,958
kWh
|
$140
-
kW-mo/yr
|
- | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $8,283 | $9,100 |
$6,425
91,639
kWh
|
$1,858
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $82,377 | $126,891 |
$40,248
538,625
kWh
|
$1,998
-
kW-mo/yr
|
$40,131
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $247 | $870 |
$247
3,411
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs