Assessment Year 2021
Principal Product vinyl and aluminum windows and doors
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $50
M
to 100
M
# of Employees 210
Plant Area 441,000
ft2
Annual Production 1,281,700
pieces
Production Hrs. Annual 4,160
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $312,444 5,956,800
kWh
Electricity Demand $169,381 19,278
kW-mo/yr
LPG $61,663 8,590
MMBtu
Waste Disposal Costs
Water Usage $5,038 2,105
Tgal
TOTAL YEARLY COSTS $548,526
RECOMMENDED SAVINGS* $56,205 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $34,049

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
01 2.4221: Install compressor air intakes in coolest locations $1,015 $4,700 $683
13,124
kWh
$332
-
kW-mo/yr
-
02 2.2437: Recover waste heat from equipment $19,767 $14,500 $13,288
255,536
kWh
$6,479
-
kW-mo/yr
-
03 2.2511: Insulate bare equipment $251 $226 $169
3,245
kWh
$82
-
kW-mo/yr
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $217 $45 $146
2,803
kWh
$71
-
kW-mo/yr
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $32,817 $55,992 $12,471
239,824
kWh
$9,066
-
kW-mo/yr
$11,280
06 2.7135: Install occupancy sensors $2,138 $1,800 $2,138
41,120
kWh
- -
TOTAL RECOMMENDED $56,205 $77,263 $28,895
555,652
kWh
$16,030
-
kW-mo/yr
$11,280
TOTAL IMPLEMENTED $34,049 $60,737 $13,300
255,751
kWh
$9,469
-
kW-mo/yr
$11,280
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs