Assessment Year | 2021 |
---|---|
Principal Product | vinyl and aluminum windows and doors |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 210 |
Plant Area |
441,000
ft2
|
Annual Production | 1,281,700
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $312,444 | 5,956,800 |
kWh
|
$0.052 | |
Electricity Demand | $169,381 | 19,278 |
kW-mo/yr
|
$8.79 | |
LPG | $61,663 | 8,590 |
MMBtu
|
$7.18 | |
Waste Disposal Costs | |||||
Water Usage | $5,038 | 2,105 |
Tgal
|
$2.39 | |
TOTAL YEARLY COSTS | $548,526 | ||||
RECOMMENDED SAVINGS* | $56,205 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $34,049 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,015 | $4,700 |
$683
13,124
kWh
|
$332
-
kW-mo/yr
|
- | |
02 | 2.2437: Recover waste heat from equipment | $19,767 | $14,500 |
$13,288
255,536
kWh
|
$6,479
-
kW-mo/yr
|
- | |
03 | 2.2511: Insulate bare equipment | $251 | $226 |
$169
3,245
kWh
|
$82
-
kW-mo/yr
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $217 | $45 |
$146
2,803
kWh
|
$71
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $32,817 | $55,992 |
$12,471
239,824
kWh
|
$9,066
-
kW-mo/yr
|
$11,280 | |
06 | 2.7135: Install occupancy sensors | $2,138 | $1,800 |
$2,138
41,120
kWh
|
- | - | |
TOTAL RECOMMENDED | $56,205 | $77,263 |
$28,895
555,652
kWh
|
$16,030
-
kW-mo/yr
|
$11,280 | ||
TOTAL IMPLEMENTED | $34,049 | $60,737 |
$13,300
255,751
kWh
|
$9,469
-
kW-mo/yr
|
$11,280 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs