Assessment Year | 2021 |
---|---|
Principal Product | wood based glass windows |
NAICS | 332321: Metal Window and Door Manufacturing |
SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
Sales Range | $50 M to 100M |
# of Employees | 454 |
Plant Area |
341,000
ft2
|
Annual Production | 1,250,280
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $250,031 | 3,870,720 |
kWh
|
$0.065 |
Electricity Demand | $35,488 | 11,301 |
kW-mo/yr
|
$3.14 |
LPG | $74,108 | 10,149 |
MMBtu
|
$7.30 |
TOTAL YEARLY COSTS | $359,627 | |||
RECOMMENDED SAVINGS* | $20,401 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,909 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,251 | $400 |
$1,972
30,819
kWh
|
$279
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,114 | $4,500 |
$1,129
17,472
kWh
|
$158
-
kW-mo/yr
|
- | $827 | |
03 | 2.4239: Eliminate or reduce compressed air usage | $4,820 | $7,000 |
$4,225
65,707
kWh
|
$595
-
kW-mo/yr
|
- | - | |
04 | 2.4239: Eliminate or reduce compressed air usage | $3,146 | $7,360 |
$1,904
30,845
kWh
|
$1,242
-
kW-mo/yr
|
- | - | |
05 | 2.2425: Use flue gases to heat process or service water | $2,963 | $4,300 | - | - |
$2,963
-
MMBtu
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,087 | $5,000 |
$953
14,756
kWh
|
$134
-
kW-mo/yr
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $604 | $200 |
$604
9,351
kWh
|
- | - | - | |
08 | 2.6127: Maintain air filters by cleaning or replacement | $304 | $52 |
$304
4,702
kWh
|
- | - | - | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $673 | $405 |
$589
9,209
kWh
|
$84
-
kW-mo/yr
|
- | - | |
10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,307 | $4,100 |
$1,307
20,110
kWh
|
- | - | - | |
11 | 2.7135: Install occupancy sensors | $1,132 | $1,720 |
$1,132
17,422
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $20,401 | $35,037 |
$14,119
220,393
kWh
|
$2,492
-
kW-mo/yr
|
$2,963
-
MMBtu
|
$827 | ||
TOTAL IMPLEMENTED | $10,909 | $21,257 |
$9,111
141,307
kWh
|
$971
-
kW-mo/yr
|
- | $827 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs