Assessment Year | 2019 |
---|---|
Principal Product | School/Commercial Bus |
NAICS | 336211: Motor Vehicle Body Manufacturing |
SIC | 3711: Motor Vehicles and Passenger Car Bodies |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
270,000
ft2
|
Annual Production | 2,500
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $130,147 | 2,649,719 |
kWh
|
$0.049 |
Electricity Demand | $207,937 | 10,086 |
kW-mo/yr
|
$20.62 |
Electricity Fees | $3,122 | - |
|
- |
Natural Gas | $87,373 | 17,604 |
MMBtu
|
$4.96 |
TOTAL YEARLY COSTS | $428,579 | |||
RECOMMENDED SAVINGS* | $85,923 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $64,500 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $48,654 | $104,076 |
$12,431
298,114
kWh
|
$36,223
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $11,093 | $7,580 |
$2,795
67,037
kWh
|
$8,298
-
kW-mo/yr
|
- | |
03 | 2.2437: Recover waste heat from equipment | $9,193 | $4,500 |
$2,348
56,302
kWh
|
$6,845
-
kW-mo/yr
|
- | |
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $8,887 | $3,200 | - |
$8,887
-
kW-mo/yr
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,363 | $2,480 |
$1,730
41,492
kWh
|
$5,033
-
kW-mo/yr
|
$(-2,400.0) | |
06 | 2.6218: Turn off equipment when not in use | $1,585 | $3,900 |
$1,585
38,017
kWh
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $763 | $400 |
$194
4,660
kWh
|
$569
-
kW-mo/yr
|
- | |
08 | 2.4221: Install compressor air intakes in coolest locations | $705 | $1,100 |
$178
4,262
kWh
|
$527
-
kW-mo/yr
|
- | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $680 | $100 |
$175
4,191
kWh
|
$505
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $85,923 | $127,336 |
$21,436
514,075
kWh
|
$66,887
-
kW-mo/yr
|
$(-2,400.0) | ||
TOTAL IMPLEMENTED | $64,500 | $116,056 |
$18,272
438,187
kWh
|
$48,628
-
kW-mo/yr
|
$(-2,400.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs