Assessment Year 2019
Principal Product large size fireplace
NAICS 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing
SIC 3433: Heating Equipment, Except Electric and Warm Air Furnaces
Sales Range $50
M
to 100
M
# of Employees 375
Plant Area 280,000
ft2
Annual Production 78,000
pieces
Production Hrs. Annual 4,160
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $385,028 4,204,649
kWh
Electricity Demand $100,105 10,803
kW-mo/yr
Natural Gas $59,640 10,602
MMBtu
Waste Disposal Costs
Water Usage $51,680 10,907,780
Tgal
TOTAL YEARLY COSTS $596,453
RECOMMENDED SAVINGS* $46,882 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $41,832

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $760 $200 $760
8,264
kWh
- - -
02 2.4227: Use compressor air filters $737 $200 $737
8,009
kWh
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $19,149 $33,942 $13,671
148,595
kWh
$3,973
-
kW-mo/yr
- $1,505
04 2.2414: Use waste heat from hot flue gases to preheat $4,815 $19,000 - - $4,815
-
MMBtu
-
05 2.4231: Reduce the pressure of compressed air to the minimum required $235 $400 $235
2,554
kWh
- - -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,293 - $1,002
10,887
kWh
$291
-
kW-mo/yr
- -
07 2.7447: Install vinyl strip / high speed / air curtain doors $19,893 $18,000 $(-1,458.0)
(-15,848)
kWh
$(-499.0)
-
kW-mo/yr
$21,850
-
MMBtu
-
TOTAL RECOMMENDED $46,882 $71,742 $14,947
162,461
kWh
$3,765
-
kW-mo/yr
$26,665
-
MMBtu
$1,505
TOTAL IMPLEMENTED $41,832 $52,342 $14,712
159,907
kWh
$3,765
-
kW-mo/yr
$21,850
-
MMBtu
$1,505
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs