Assessment Year | 2019 |
---|---|
Principal Product | large size fireplace |
NAICS | 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing |
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $50 M to 100M |
# of Employees | 375 |
Plant Area |
280,000
ft2
|
Annual Production | 78,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $385,028 | 4,204,649 |
kWh
|
$0.092 | |
Electricity Demand | $100,105 | 10,803 |
kW-mo/yr
|
$9.27 | |
Natural Gas | $59,640 | 10,602 |
MMBtu
|
$5.63 | |
Waste Disposal Costs | |||||
Water Usage | $51,680 | 10,907,780 |
Tgal
|
$0.005 | |
TOTAL YEARLY COSTS | $596,453 | ||||
RECOMMENDED SAVINGS* | $46,882 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $41,832 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $760 | $200 |
$760
8,264
kWh
|
- | - | - | |
02 | 2.4227: Use compressor air filters | $737 | $200 |
$737
8,009
kWh
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,149 | $33,942 |
$13,671
148,595
kWh
|
$3,973
-
kW-mo/yr
|
- | $1,505 | |
04 | 2.2414: Use waste heat from hot flue gases to preheat | $4,815 | $19,000 | - | - |
$4,815
-
MMBtu
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $235 | $400 |
$235
2,554
kWh
|
- | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,293 | - |
$1,002
10,887
kWh
|
$291
-
kW-mo/yr
|
- | - | |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $19,893 | $18,000 |
$(-1,458.0)
(-15,848)
kWh
|
$(-499.0)
-
kW-mo/yr
|
$21,850
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $46,882 | $71,742 |
$14,947
162,461
kWh
|
$3,765
-
kW-mo/yr
|
$26,665
-
MMBtu
|
$1,505 | ||
TOTAL IMPLEMENTED | $41,832 | $52,342 |
$14,712
159,907
kWh
|
$3,765
-
kW-mo/yr
|
$21,850
-
MMBtu
|
$1,505 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs