Assessment Year | 2017 |
---|---|
Principal Product | plastic parts for automobiles, also appliances |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 78 |
Plant Area |
136,000
ft2
|
Annual Production | 950,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $213,115 | 4,344,918 |
kWh
|
$0.049 |
Electricity Demand | $212,667 | 10,337 |
kW-mo/yr
|
$20.57 |
TOTAL YEARLY COSTS | $425,782 | |||
RECOMMENDED SAVINGS* | $13,830 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,830 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $2,360 | $2,860 |
$2,206
45,024
kWh
|
$154
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,030 | $11,846 |
$1,104
22,536
kWh
|
$926
-
kW-mo/yr
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,483 | $6,643 |
$1,261
25,728
kWh
|
$2,222
-
kW-mo/yr
|
|
04 | 2.4221: Install compressor air intakes in coolest locations | $2,435 | $1,320 |
$1,149
23,452
kWh
|
$1,286
-
kW-mo/yr
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,522 | $1,000 |
$1,897
38,708
kWh
|
$1,625
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $13,830 | $23,669 |
$7,617
155,448
kWh
|
$6,213
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $13,830 | $23,669 |
$7,617
155,448
kWh
|
$6,213
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs