Assessment Year 1996
Principal Product Polypropylene and polyethylene plastic slip sheets
NAICS
n/a
SIC 3081: Unsupported Plastics Film and Sheet
Sales Range $5
M
to 10
M
# of Employees 30
Plant Area 45,050
ft2
Annual Production 12,500,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $36,584 530,481
kWh
Electricity Demand $16,380 5,414
kW-mo/yr
Electricity Fees $4,640 -
Natural Gas $1,055 220
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $10,461 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings
01 2.8121: Apply for tax-free status for energy purchases $4,500 $9,000 n/a - - $4,500 -
02 3.5315: Lease / purchase baler; sell cardboard to recycler $2,270 $5,000 n/a - - - $2,270
-
lb
03 2.7121: Utilize daylight whenever possible in lieu of artificial light $1,530 - n/a $1,530
22,567
kWh
- - -
04 2.7124: Make a practice of turning off lights when not needed $900 $134 n/a $820
12,016
kWh
$80
-
kW-mo/yr
- -
05 2.6212: Turn off equipment during breaks, reduce operating time $510 - n/a $510
7,620
kWh
- - -
06 3.5212: Regrind, reuse, or sell scrap plastic parts $560 - n/a - - - $560
-
lb
07 2.4133: Use most efficient type of electric motors $191 $373 n/a $171
2,345
kWh
$20
-
kW-mo/yr
- -
TOTAL RECOMMENDED $10,461 $14,507 $3,031
44,548
kWh
$100
-
kW-mo/yr
$4,500 $2,830
-
lb
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs