Assessment Year 2016
Principal Product assembly of electroic connectors
NAICS 334419: Other Electronic Component Manufacturing
SIC 3643: Current-Carrying Wiring Devices
Sales Range $50
M
to 100
M
# of Employees 122
Plant Area 43,000
ft2
Annual Production 15,000,000
pieces
Production Hrs. Annual 4,000
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $147,934 1,585,200
kWh
Electricity Demand $41,795 4,694
kW-mo/yr
Natural Gas $4,161 457
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $22,985 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $22,719

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7135: Install occupancy sensors $3,536 $1,500 $3,536
38,020
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $10,259 $37,722 $7,971
85,712
kWh
$2,288
-
kW-mo/yr
03 2.4221: Install compressor air intakes in coolest locations $1,678 $1,200 $1,678
18,040
kWh
-
04 2.6127: Maintain air filters by cleaning or replacement $266 - $266
2,859
kWh
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,246 $1,212 $7,246
80,511
kWh
-
TOTAL RECOMMENDED $22,985 $41,634 $20,697
225,142
kWh
$2,288
-
kW-mo/yr
TOTAL IMPLEMENTED $22,719 $41,634 $20,431
222,283
kWh
$2,288
-
kW-mo/yr
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs