| Assessment Year | 2025 |
|---|---|
| Principal Product | Pre-engineered Metal Buildings |
| NAICS | 332311: Prefabricated Metal Building and Component Manufacturing |
| SIC | 3448: Prefabricated Metal Buildings and Components |
| Sales Range | $50 M to 100M |
| # of Employees | 110 |
| Plant Area |
140,000
ft2
|
| Annual Production | 16,900
ton
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $340,953 | 2,920,608 |
kWh
|
$0.12 | |
| Electricity Demand | $108,795 | 8,384 |
kW-mo/yr
|
$12.98 | |
| Natural Gas | $110,031 | 13,276 |
MMBtu
|
$8.29 | |
| Waste Disposal Costs | |||||
| Water Usage | $4,261 | 575 |
Tgal
|
$7.41 | |
| Water Disposal | $4,931 | 575 |
Tgal
|
$8.58 | |
| TOTAL YEARLY COSTS | $568,971 | ||||
| RECOMMENDED SAVINGS* | $189,733 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|
| 01 | 4.131: Modify process to reduce material use/cost | $106,940 | $8,000 | - | - | $106,940 | |
| 02 | 2.9114: Use solar heat to make electricty | $51,928 | $289,763 |
$51,928
444,970
kWh
|
- | - | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,284 | $4,000 |
$17,284
148,106
kWh
|
- | - | |
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,788 | $4,000 |
$6,788
58,165
kWh
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,446 | $1,500 |
$2,839
24,325
kWh
|
$607
-
kW-mo/yr
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,652 | $3,850 |
$1,256
10,763
kWh
|
$396
-
kW-mo/yr
|
- | |
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,402 | $1,500 |
$1,402
12,012
kWh
|
- | - | |
| 08 | 2.6231: Utilize controls to operate equipment only when needed | $293 | $170 |
$293
2,511
kWh
|
- | - | |
| TOTAL RECOMMENDED | $189,733 | $312,783 |
$81,790
700,852
kWh
|
$1,003
-
kW-mo/yr
|
$106,940 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs