Assessment Year 2016
Principal Product Machine tools
NAICS 333517: Machine Tool Manufacturing
SIC 3541: Machine Tools, Metal Cutting Types
Sales Range $10
M
to 50
M
# of Employees 110
Plant Area 208,000
ft2
Annual Production 1,000
units
Production Hrs. Annual 5,800
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $248,851 3,940,000
kWh
Electricity Demand $90,222 11,639
kW-mo/yr
Natural Gas $43,812 9,963
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $74,262 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7232: Replace existing hvac unit with high efficiency model $19,101 $70,000 $14,869
235,416
kWh
$4,232
-
kW-mo/yr
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $17,180 $27,600 $13,699
216,891
kWh
$3,481
-
kW-mo/yr
-
03 2.4221: Install compressor air intakes in coolest locations $6,654 $5,000 $5,305
84,000
kWh
$1,349
-
kW-mo/yr
-
04 2.2437: Recover waste heat from equipment $3,839 $3,225 - - $3,839
-
MMBtu
05 2.4224: Upgrade controls on compressors $9,678 $45,000 $9,678
153,228
kWh
- -
06 4.512: Condense operation into one building $3,585 - $3,585
56,768
kWh
- -
07 4.512: Condense operation into one building $7,503 - $3,950
62,540
kWh
$1,209
-
kW-mo/yr
$2,344
-
MMBtu
08 2.4133: Use most efficient type of electric motors $6,722 $7,341 $5,156
81,630
kWh
$1,566
-
kW-mo/yr
-
TOTAL RECOMMENDED $74,262 $158,166 $56,242
890,473
kWh
$11,837
-
kW-mo/yr
$6,183
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs