| Annual Production | 1,000
units
|
| Production Hrs. Annual | 5,800
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $248,851 | 3,940,000 |
kWh
|
$0.063 |
| Electricity Demand | $90,222 | 11,639 |
kW-mo/yr
|
$7.75 |
| Natural Gas | $43,812 | 9,963 |
MMBtu
|
$4.40 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $74,262 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7232: Replace existing hvac unit with high efficiency model | $19,101 | $70,000 |
$14,869
235,416
kWh
|
$4,232
-
kW-mo/yr
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,180 | $27,600 |
$13,699
216,891
kWh
|
$3,481
-
kW-mo/yr
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $6,654 | $5,000 |
$5,305
84,000
kWh
|
$1,349
-
kW-mo/yr
|
- | |
| 04 | 2.2437: Recover waste heat from equipment | $3,839 | $3,225 | - | - |
$3,839
-
MMBtu
|
|
| 05 | 2.4224: Upgrade controls on compressors | $9,678 | $45,000 |
$9,678
153,228
kWh
|
- | - | |
| 06 | 4.512: Condense operation into one building | $3,585 | - |
$3,585
56,768
kWh
|
- | - | |
| 07 | 4.512: Condense operation into one building | $7,503 | - |
$3,950
62,540
kWh
|
$1,209
-
kW-mo/yr
|
$2,344
-
MMBtu
|
|
| 08 | 2.4133: Use most efficient type of electric motors | $6,722 | $7,341 |
$5,156
81,630
kWh
|
$1,566
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $74,262 | $158,166 |
$56,242
890,473
kWh
|
$11,837
-
kW-mo/yr
|
$6,183
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs