Assessment Year | 2016 |
---|---|
Principal Product | Custom casework for residential and commercial applications |
NAICS | 337121: Upholstered Household Furniture Manufacturing |
SIC | 2511: Wood Household Furniture, Except Upholstered |
Sales Range | $10 M to 50M |
# of Employees | 83 |
Plant Area |
280,000
ft2
|
Annual Production | 200,000
pieces
|
Production Hrs. Annual | 2,100
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $278,203 | 3,763,200 |
kWh
|
$0.074 |
Electricity Demand | $86,483 | 13,356 |
kW-mo/yr
|
$6.48 |
Natural Gas | $86,159 | 10,696 |
MMBtu
|
$8.06 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $208,381 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $45,907 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat | $108,895 | $375,000 |
$62,489
845,582
kWh
|
$31,287
-
kW-mo/yr
|
$15,119
-
MMBtu
|
|
02 | 3.1161: Eliminate/reduce an operation | $8,491 | - |
$4,140
56,000
kWh
|
$4,351
-
kW-mo/yr
|
- | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $19,426 | - | - |
$19,426
-
kW-mo/yr
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,717 | - |
$1,144
15,477
kWh
|
$573
-
kW-mo/yr
|
- | |
05 | 2.4239: Eliminate or reduce compressed air usage | $12,192 | $12,000 |
$9,803
132,603
kWh
|
$2,389
-
kW-mo/yr
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,397 | $1,500 |
$931
12,599
kWh
|
$466
-
kW-mo/yr
|
- | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,703 | $930 |
$2,466
33,357
kWh
|
$1,237
-
kW-mo/yr
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $45,907 | $136,500 |
$30,593
413,826
kWh
|
$15,314
-
kW-mo/yr
|
- | |
09 | 2.6212: Turn off equipment during breaks, reduce operating time | $6,653 | - |
$6,653
90,000
kWh
|
- | - | |
TOTAL RECOMMENDED | $208,381 | $525,930 |
$118,219
1,599,444
kWh
|
$75,043
-
kW-mo/yr
|
$15,119
-
MMBtu
|
||
TOTAL IMPLEMENTED | $45,907 | $136,500 |
$30,593
413,826
kWh
|
$15,314
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs