| Assessment Year | 2015 |
|---|---|
| Principal Product | eletronic connectors |
| NAICS | 334417: Electronic Connector Manufacturing |
| SIC | 3643: Current-Carrying Wiring Devices |
| Sales Range | $10 M to 50M |
| # of Employees | 166 |
| Plant Area |
75,000
ft2
|
| Annual Production | 25,000,000
pieces
|
| Production Hrs. Annual | 4,216
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $188,504 | 2,582,400 |
kWh
|
$0.073 |
| Natural Gas | $1,630 | 208 |
MMBtu
|
$7.82 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,094 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $26,943 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $5,337 | $1,752 |
$5,337
76,245
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,900 | $960 |
$6,900
98,524
kWh
|
|
| 03 | 2.4239: Eliminate or reduce compressed air usage | $11,344 | $3,200 |
$11,344
162,000
kWh
|
|
| 04 | 2.4221: Install compressor air intakes in coolest locations | $3,362 | $1,160 |
$3,362
48,030
kWh
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,151 | - |
$1,151
15,285
kWh
|
|
| TOTAL RECOMMENDED | $28,094 | $7,072 |
$28,094
400,084
kWh
|
||
| TOTAL IMPLEMENTED | $26,943 | $7,072 |
$26,943
384,799
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs