| Assessment Year | 2002 |
|---|---|
| Principal Product | Paper Envelopes |
| NAICS |
n/a
|
| SIC | 2677: Envelopes |
| Sales Range | $10 M to 50M |
| # of Employees | 240 |
| Plant Area |
250,000
ft2
|
| Annual Production | 2,000,000,000
pieces
|
| Production Hrs. Annual | 6,192
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $457,099 | 9,263,376 |
kWh
|
$0.049 |
| Electricity Demand | $89,737 | 22,310 |
kW-mo/yr
|
$4.02 |
| Electricity Fees | $65,120 | - |
|
- |
| Natural Gas | $56,465 | 6,083 |
MMBtu
|
$9.28 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,336 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,036 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.8123: Pay utility bills on time | $5,506 | - | - | - | $5,506 | |
| 02 | 2.4314: Use synthetic lubricant | $3,150 | - |
$2,800
53,538
kWh
|
$350
-
kW-mo/yr
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,150 | - |
$1,685
32,273
kWh
|
$465
-
kW-mo/yr
|
- | |
| 04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $270 | - |
$270
5,177
kWh
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $260 | $468 |
$243
4,660
kWh
|
$17
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $11,336 | $468 |
$4,998
95,648
kWh
|
$832
-
kW-mo/yr
|
$5,506 | ||
| TOTAL IMPLEMENTED | $6,036 | $468 |
$513
9,837
kWh
|
$17
-
kW-mo/yr
|
$5,506 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs