Assessment Year | 2002 |
---|---|
Principal Product | Paper Envelopes |
NAICS |
n/a
|
SIC | 2677: Envelopes |
Sales Range | $10 M to 50M |
# of Employees | 240 |
Plant Area |
250,000
ft2
|
Annual Production | 2,000,000,000
pieces
|
Production Hrs. Annual | 6,192
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $457,099 | 9,263,376 |
kWh
|
$0.049 |
Electricity Demand | $89,737 | 22,310 |
kW-mo/yr
|
$4.02 |
Electricity Fees | $65,120 | - |
|
- |
Natural Gas | $56,465 | 6,083 |
MMBtu
|
$9.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,336 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,036 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.8123: Pay utility bills on time | $5,506 | - | - | - | $5,506 | |
02 | 2.4314: Use synthetic lubricant | $3,150 | - |
$2,800
53,538
kWh
|
$350
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,150 | - |
$1,685
32,273
kWh
|
$465
-
kW-mo/yr
|
- | |
04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $270 | - |
$270
5,177
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $260 | $468 |
$243
4,660
kWh
|
$17
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $11,336 | $468 |
$4,998
95,648
kWh
|
$832
-
kW-mo/yr
|
$5,506 | ||
TOTAL IMPLEMENTED | $6,036 | $468 |
$513
9,837
kWh
|
$17
-
kW-mo/yr
|
$5,506 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs