Assessment Year | 2014 |
---|---|
Principal Product | Water-based latex |
NAICS | 325211: Plastics Material and Resin Manufacturing |
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $100 M to 500M |
# of Employees | 51 |
Plant Area |
180,000
ft2
|
Annual Production | 180,000,000
lb
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $323,777 | 5,553,636 |
kWh
|
$0.058 |
Electricity Demand | $92,112 | 8,847 |
kW-mo/yr
|
$10.41 |
Natural Gas | $417,377 | 74,166 |
MMBtu
|
$5.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $170,271 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $41,019 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $27,719 | $74,400 |
$22,086
378,840
kWh
|
$5,633
-
kW-mo/yr
|
- | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $7,000 | $15,000 | - | - |
$7,000
-
MMBtu
|
|
03 | 2.1224: Replace boiler | $32,000 | $65,000 | - | - |
$32,000
-
MMBtu
|
|
04 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $47,644 | $117,000 |
$37,953
651,000
kWh
|
$9,691
-
kW-mo/yr
|
- | |
05 | 2.7425: Clean or color roof to reduce solar load | $13,436 | $24,000 |
$906
15,545
kWh
|
- |
$12,530
-
MMBtu
|
|
06 | 3.1161: Eliminate/reduce an operation | $7,727 | - |
$6,556
112,500
kWh
|
$1,171
-
kW-mo/yr
|
- | |
07 | 2.2437: Recover waste heat from equipment | $3,778 | $7,000 | - | - |
$3,778
-
MMBtu
|
|
08 | 2.4221: Install compressor air intakes in coolest locations | $13,300 | $5,000 |
$10,593
181,691
kWh
|
$2,707
-
kW-mo/yr
|
- | |
09 | 2.7221: Lower temperature during the winter season and vice-versa | $6,495 | - |
$2,217
38,020
kWh
|
$593
-
kW-mo/yr
|
$3,685
-
MMBtu
|
|
10 | 2.7442: Keep doors and windows shut when not on use | $11,172 | $24,000 | - | - |
$11,172
-
MMBtu
|
|
TOTAL RECOMMENDED | $170,271 | $331,400 |
$80,311
1,377,596
kWh
|
$19,795
-
kW-mo/yr
|
$70,165
-
MMBtu
|
||
TOTAL IMPLEMENTED | $41,019 | $79,400 |
$32,679
560,531
kWh
|
$8,340
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |