Assessment Year | 2014 |
---|---|
Principal Product | sportings goods |
NAICS | 339920: Sporting and Athletic Goods Manufacturing |
SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 540 |
Plant Area |
140,000
ft2
|
Annual Production | 150,000
pieces
|
Production Hrs. Annual | 5,300
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $264,969 | 4,343,760 |
kWh
|
$0.061 |
Electricity Demand | $70,449 | 9,602 |
kW-mo/yr
|
$7.34 |
Natural Gas | $11,414 | 1,115 |
MMBtu
|
$10.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $132,396 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $106,527 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $11,156 | $7,200 |
$11,156
185,938
kWh
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,028 | $38,640 |
$9,424
157,065
kWh
|
$2,604
-
kW-mo/yr
|
- | - | |
03 | 2.7134: Use photocell controls | $4,586 | $2,450 |
$4,586
76,440
kWh
|
- | - | - | |
04 | 2.7221: Lower temperature during the winter season and vice-versa | $13,499 | - |
$6,198
103,302
kWh
|
$1,893
-
kW-mo/yr
|
$5,408
-
MMBtu
|
- | |
05 | 2.7442: Keep doors and windows shut when not on use | $2,210 | - | - | - |
$2,210
-
MMBtu
|
- | |
06 | 4.122: Develop standard procedures to improve internal yields | $60,368 | $50,000 | - | - | - | $60,368 | |
07 | 4.512: Condense operation into one building | $16,179 | $85,000 |
$12,303
201,695
kWh
|
$3,344
-
kW-mo/yr
|
$532
-
MMBtu
|
- | |
08 | 2.4226: Use / purchase optimum sized compressor | $12,370 | $40,000 |
$9,692
161,525
kWh
|
$2,678
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $132,396 | $223,290 |
$53,359
885,965
kWh
|
$10,519
-
kW-mo/yr
|
$8,150
-
MMBtu
|
$60,368 | ||
TOTAL IMPLEMENTED | $106,527 | $183,290 |
$37,469
621,138
kWh
|
$5,948
-
kW-mo/yr
|
$2,742
-
MMBtu
|
$60,368 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs