| Assessment Year | 2013 |
|---|---|
| Principal Product | Truck Tank Trailer |
| NAICS | 336212: Truck Trailer Manufacturing |
| SIC | 3715: Truck Trailers |
| Sales Range | $50 M to 100M |
| # of Employees | 250 |
| Plant Area |
146,000
ft2
|
| Annual Production | 963
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $205,587 | 3,033,200 |
kWh
|
$0.068 |
| Natural Gas | $35,122 | 5,818 |
MMBtu
|
$6.04 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $30,854 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $29,175 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $22,032 | $90,880 |
$22,032
324,000
kWh
|
- | |
| 02 | 2.7144: Install spectral reflectors / delamp | $1,584 | - |
$1,584
23,296
kWh
|
- | |
| 03 | 2.7496: Install partitions to reduce size of conditioned space | $1,679 | - |
$1,679
24,693
kWh
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,270 | $400 |
$1,270
18,680
kWh
|
- | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $1,891 | $1,160 |
$1,891
27,803
kWh
|
- | |
| 06 | 2.6127: Maintain air filters by cleaning or replacement | $1,045 | $150 |
$1,045
15,373
kWh
|
- | |
| 07 | 2.7135: Install occupancy sensors | $218 | $190 |
$218
3,200
kWh
|
- | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $418 | $1,000 |
$418
6,336
kWh
|
- | |
| 09 | 2.2442: Preheat combustion air with waste heat | $717 | $2,000 | - |
$717
-
MMBtu
|
|
| TOTAL RECOMMENDED | $30,854 | $95,780 |
$30,137
443,381
kWh
|
$717
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $29,175 | $95,780 |
$28,458
418,688
kWh
|
$717
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs