| Assessment Year | 2013 |
|---|---|
| Principal Product | dry and condensed dairy products |
| NAICS | 311514: Dry, Condensed, and Evaporated Dairy Product Manufacturing |
| SIC | 2023: Dry, Condensed, and Evaporated Dairy Products |
| Sales Range | $10 M to 50M |
| # of Employees | 121 |
| Plant Area |
175,000
ft2
|
| Annual Production | 1,560
ton
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $510,942 | 10,218,840 |
kWh
|
$0.050 |
| Electricity Demand | $100 | 10 |
kW-mo/yr
|
$10.00 |
| Natural Gas | $187,009 | 18,701 |
MMBtu
|
$10.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $167,601 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $64,408 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,576 | $14,260 |
$6,126
112,520
kWh
|
$2,450
-
kW-mo/yr
|
- | |
| 02 | 2.7135: Install occupancy sensors | $6,417 | $3,000 |
$6,417
128,340
kWh
|
- | - | |
| 03 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $4,329 | - | - | - |
$4,329
-
MMBtu
|
|
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,415 | - |
$1,011
20,220
kWh
|
$404
-
kW-mo/yr
|
- | |
| 05 | 2.1113: Reduce combustion air flow to optimum | $48,000 | $2,270 | - | - |
$48,000
-
MMBtu
|
|
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,024 | $1,150 |
$3,557
71,123
kWh
|
$1,467
-
kW-mo/yr
|
- | |
| 07 | 2.7221: Lower temperature during the winter season and vice-versa | $27,737 | - |
$11,175
223,504
kWh
|
$3,226
-
kW-mo/yr
|
$13,336
-
MMBtu
|
|
| 08 | 2.4221: Install compressor air intakes in coolest locations | $4,303 | $1,160 |
$2,427
48,535
kWh
|
$1,876
-
kW-mo/yr
|
- | |
| 09 | 2.2692: Use outside cold water source as a supply of cooling water | $61,800 | $450,000 |
$4,533
90,667
kWh
|
$2,267
-
kW-mo/yr
|
$55,000
-
MMBtu
|
|
| TOTAL RECOMMENDED | $167,601 | $471,840 |
$35,246
694,909
kWh
|
$11,690
-
kW-mo/yr
|
$120,665
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $64,408 | $19,530 |
$13,554
261,080
kWh
|
$2,854
-
kW-mo/yr
|
$48,000
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs