Assessment Year | 1994 |
---|---|
Principal Product | Clay Pipes |
NAICS |
n/a
|
SIC | 3259: Structural Clay Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 210 |
Plant Area |
871,200
ft2
|
Annual Production | 32,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $472,030 | 4,789,273 |
kWh
|
$0.099 |
Natural Gas | $1,619,773 | 569,696 |
MMBtu
|
$2.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $171,430 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,657 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $2,055 | $1,298 |
$2,055
21,102
kWh
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,720 | $21,935 |
$11,720
119,578
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,368 | $900 |
$11,368
116,061
kWh
|
- | |
04 | 2.2511: Insulate bare equipment | $116,693 | $13,400 | - |
$116,693
-
MMBtu
|
|
05 | 2.4314: Use synthetic lubricant | $781 | - |
$781
7,913
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,453 | $4,943 |
$3,453
35,170
kWh
|
- | |
07 | 2.2437: Recover waste heat from equipment | $25,360 | $12,000 | - |
$25,360
-
MMBtu
|
|
TOTAL RECOMMENDED | $171,430 | $54,476 |
$29,377
299,824
kWh
|
$142,053
-
MMBtu
|
||
TOTAL IMPLEMENTED | $17,657 | $7,141 |
$17,657
180,246
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs