Assessment Year | 2012 |
---|---|
Principal Product | Electric motor parts |
NAICS | 332119: Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 260 |
Plant Area |
191,412
ft2
|
Annual Production | 47,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $278,808 | 5,118,520 |
kWh
|
$0.054 |
Electricity Demand | $31,445 | 12,562 |
kW-mo/yr
|
$2.50 |
Electricity Fees | $56,468 | - |
|
- |
Natural Gas | $285,245 | 54,123 |
MMBtu
|
$5.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $146,266 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $105,347 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $57,095 | $67,348 | - | - | - |
$57,095
-
MMBtu
|
- | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $28,732 | $29,201 | - | - | - |
$28,732
-
MMBtu
|
- | |
03 | 2.8112: Combine utility meters | $19,635 | $10,000 | - | - | $19,635 | - | - | |
04 | 2.1113: Reduce combustion air flow to optimum | $15,197 | $16,000 | - | - | - |
$16,037
-
MMBtu
|
$(-840.0) | |
05 | 2.7231: Use radiant heater for spot heating | $11,800 | $22,100 | - | - | - |
$11,800
-
MMBtu
|
- | |
06 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $6,087 | $3,554 | - | - | - |
$6,087
-
MMBtu
|
- | |
07 | 2.6218: Turn off equipment when not in use | $5,395 | $5,400 |
$5,395
128,909
kWh
|
- | - | - | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $896 | $221 |
$803
19,179
kWh
|
$93
-
kW-mo/yr
|
- | - | - | |
09 | 2.7134: Use photocell controls | $507 | $560 |
$507
12,110
kWh
|
- | - | - | - | |
10 | 2.7135: Install occupancy sensors | $455 | $480 |
$455
10,877
kWh
|
- | - | - | - | |
11 | 2.4221: Install compressor air intakes in coolest locations | $467 | $480 |
$467
11,169
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $146,266 | $155,344 |
$7,627
182,244
kWh
|
$93
-
kW-mo/yr
|
$19,635 |
$119,751
-
MMBtu
|
$(-840.0) | ||
TOTAL IMPLEMENTED | $105,347 | $125,790 |
$7,627
182,244
kWh
|
$93
-
kW-mo/yr
|
- |
$97,627
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs